Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38558544

RESUMEN

AIM: Behavioral psychological symptoms of dementia (BPSD) are sometimes difficult to treat due to severe psychiatric symptoms such as delusions of poisoning and violent behavior. Moreover, in cases of parental neglect, the management of these psychiatric symptoms becomes more difficult. Therefore, home-visiting doctors sometimes have to manage patients with BPSD and severe psychiatric symptoms, and a new approach is needed. In this case report, the effect of blonanserin transdermal patch on these patients is to be highlighted. METHODS: The patient is a 91-year-old woman diagnosed with Alzheimer's disease. She had severe BPSD such as delusion of robbery and violent behavior, and refused oral medications including memantine and yokukansan. Then she was treated with blonanserin transdermal patch (20 mg/day). The severity of psychiatric symptoms of BPSD was assessed over time using the Neuropsychiatric Inventory (NPI) score. Moreover, the patient's cognitive function was also assessed over time by Mini-Mental State Examination (MMSE). RESULTS: After the introduction of blonanserin patch, the patient's psychiatric symptoms were stabilized markedly, and both NPI and MMSE scores improved. The patient was able to stay at home calmly and was mentally well stabilized to the extent that she did not require hospitalization. No apparent side effects were admitted. CONCLUSIONS: The blonanserin transdermal patch may be able to manage BPSD at home and is effective in patients who refuse oral medications. Home-visiting doctors may consider the use of blonanserin patches at home for patients with severe BPSD, manifesting as delusions of poisoning and refusing oral drugs.

2.
J Arrhythm ; 40(2): 247-255, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38586837

RESUMEN

Background: Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study. Methods: Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam-pops were compared. Results: A total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15-35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature-guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam-pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs). Conclusions: For vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam-pops may be mitigated through power titration even in high CFs.

3.
Heart Rhythm ; 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38460753

RESUMEN

BACKGROUND: Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging. OBJECTIVE: The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms. METHODS: Sinus node activation was mapped in patients undergoing catheter ablation by a multielectrode array with a close indifferent electrode (CIE) embedded in the distal end of the catheter shaft. An equal number of points was sequentially acquired at each site with use of CIE as a reference first and subsequently with WCT. Uni-EGMs, bipolar EGMs, and the earliest activation area (defined as the area activated in the first 10 ms of the beat) were compared between CIE- and WCT-based activation maps. RESULTS: Seventeen patients (61 ± 18 years; 76% male) were studied. Uni-EGM voltages acquired with CIE were significantly larger than (n = 11) or comparable to (n = 4) those acquired with WCT. When points from the entire cohort were analyzed altogether, unipolar voltages and their maximum negative dV/dT and bipolar voltages recorded with CIE were significantly larger than those recorded with WCT (2.36 [1.42-3.79] mV vs 1.96 [1.25-3.03] mV, P < .0001; 0.40 [0.18-0.77] mV/s vs 0.35 [0.15-0.71] mV/s, P < .0001; and 1.46 [0.66-2.81] mV vs 1.33 [0.54-2.64] mV, P < .0001, respectively). The earliest activation area was significantly smaller in CIE-based activation maps than in WCT-based ones (0.3 [0.7-1.4] cm2 vs 0.6 [1.0-1.8] cm2, P = .01). CONCLUSION: CIE-based maps were associated with an approximately 20% increase in unipolar voltage and may highlight the origin of a focal activation more clearly than WCT-based ones.

5.
Pacing Clin Electrophysiol ; 46(12): 1536-1545, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37957924

RESUMEN

BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.


Asunto(s)
Ablación por Catéter , Vapor , Humanos , Animales , Porcinos , Irrigación Terapéutica , Diseño de Equipo , Catéteres
6.
Artículo en Inglés | MEDLINE | ID: mdl-37946002

RESUMEN

PURPOSE: Radiofrequency (RF) ablation with half-normal saline (HNS) irrigation is reported to potentially enlarge local lesion compared to normal saline (NS) in power-controlled ablation (PC-Abl). However, the effect of HNS-irrigation in temperature-flow-controlled ablation (TFC-Abl) on lesion characteristics is unknown. We compared this between TFC-Abl with QDOT-Micro™ catheter and PC-Abl with Thermocool SmartTouch SF™ catheter (STSF). METHODS: RF-application with NS (n = 480) and HNS (n = 480) irrigation were performed on swine myocardium placed in a circulating saline bath. Lesion characteristics without steam-pops under various conditions (target AI, 400/550; ablation power, 30/50 W; contact force, 10/20/30 g; catheter orientation, perpendicular/parallel) were assessed and compared between two irrigants. RESULTS: After matching, 343 lesions without steam-pops in each group were evaluated. In PC-Abl, lesion size did not differ between two groups (NS, 188 ± 97 vs. HNS, 200 ± 95 mm3, p = 0.28 in volume; 33.9 ± 7.3 vs. 34.8 ± 9.5 mm2, p = 0.34 in surface area; and 4.0 ± 1.0 vs. 4.0 ± 1.0 mm, p = 0.81 in depth), but steam-pops were more frequently observed with HNS-irrigation (23.8% vs. 37.9%, p = 0.001). Contrary, in TFC-Abl, HNS-irrigation produced significantly larger (214 ± 106 vs. 243 ± 128 mm3, p = 0.017) and deeper (4.0 ± 1.0 vs. 4.3 ± 1.1 mm, p = 0.002) lesions without increasing the risk of steam-pops (15.0% vs 15.0%, p = 0.99). Automatic temperature-guided titration was more frequently observed in HNS-irrigation (54.8% vs. 78.5%, p < 0.001). CONCLUSIONS: TFC-Abl with QDOT-Micro™ catheter utilizing HNS-irrigation might increase volume and depth of local lesion without increasing the risk of stem-pops compared to NS-irrigation. Power-controlled ablation with HNS-irrigation showed similar focal lesion with higher incidence of steam-pops (SPs) compared to normal saline (NS) irrigation. Contrary, temperature-flow-controlled ablation with HNS-irrigation provided larger and deeper lesion than NS-irrigation with similar incidence of SPs. ns, p > 0.05; *, 0.01 < p ≤ 0.05; **, 0.005 < p ≤ 0.01. HNS, half-normal saline; NS, normal saline.

7.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37899173

RESUMEN

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Asunto(s)
Ablación por Catéter , Solución Salina , Animales , Porcinos , Ventrículos Cardíacos/patología , Corazón , Catéteres , Ablación por Catéter/métodos , Diseño de Equipo , Impedancia Eléctrica
8.
JMIR Nurs ; 6: e51303, 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37634203

RESUMEN

BACKGROUND: Documentation tasks comprise a large percentage of nurses' workloads. Nursing records were partially based on a report from the patient. However, it is not a verbatim transcription of the patient's complaints but a type of medical record. Therefore, to reduce the time spent on nursing documentation, it is necessary to assist in the appropriate conversion or citation of patient reports to professional records. However, few studies have been conducted on systems for capturing patient reports in electronic medical records. In addition, there have been no reports on whether such a system reduces the time spent on nursing documentation. OBJECTIVE: This study aims to develop a patient self-reporting system that appropriately converts data to nursing records and evaluate its effect on reducing the documenting burden for nurses. METHODS: An electronic medical record-connected questionnaire and a preadmission nursing questionnaire were administered. The questionnaire responses entered by the patients were quoted in the patient profile for inpatient assessment in the nursing system. To clarify its efficacy, this study examined whether the use of the electronic questionnaire system saved the nurses' time entering the patient profile admitted between August and December 2022. It also surveyed the usability of the electronic questionnaire between April and December 2022. RESULTS: A total of 3111 (78%) patients reported that they answered the electronic medical questionnaire by themselves. Of them, 2715 (88%) felt it was easy to use and 2604 (85%) were willing to use it again. The electronic questionnaire was used in 1326 of 2425 admission cases (use group). The input time for the patient profile was significantly shorter in the use group than in the no-use group (P<.001). Stratified analyses showed that in the internal medicine wards and in patients with dependent activities of daily living, nurses took 13%-18% (1.3 to 2 minutes) less time to enter patient profiles within the use group (both P<.001), even though there was no difference in the amount of information. By contrast, in the surgical wards and in the patients with independent activities of daily living, there was no difference in the time to entry (P=.50 and P=.20, respectively), but there was a greater amount of information in the use group. CONCLUSIONS: The study developed and implemented a system in which self-reported patient data were captured in the hospital information network and quoted in the nursing system. This system contributes to improving the efficiency of nurses' task recordings.

9.
Glia ; 71(12): 2753-2769, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37571859

RESUMEN

Neuronal ceroid lipofuscinosis is a group of pediatric neurodegenerative diseases. One of their causative genes, CLN10/CtsD, encodes cathepsin D, a major lysosomal protease. Central nervous system (CNS)-specific CtsD-deficient mice exhibit a neurodegenerative disease phenotype with accumulation of ceroid lipofuscins, granular osmiophilic deposits, and SQSTM1/p62. We focused on activated astrocytes and microglia in this neurodegenerative mouse brain, since there are few studies on the relationship between these accumulators and lysosomes in these glial cells. Activated microglia and astrocytes in this mouse thalamus at p24 were increased by approximately 2.5- and 4.6-fold compared with the control, while neurons were decreased by approximately half. Granular osmiophilic deposits were detected in microglial cell bodies and extended their processes in the thalamus. LAMP1-positive lysosomes, but not SQSTM1/p62 aggregates, accumulated in microglia of this mouse thalamus, whereas both lysosomes and SQSTM1/p62 aggregates accumulated in its astrocytes. TUNEL-positive signals were observed mainly in microglia, but few were observed in neurons and astrocytes. These signals were fragmented DNA from degenerated neurons engulfed by microglia or in the lysosomes of microglia. Abnormal autophagic vacuoles also accumulated in the lysosomes of microglia. Granular osmiophilic deposit-like structures localized to LAMP1-positive lysosomes in CtsD-deficient astrocytes. SQSTM1/p62-positive but LAMP1-negative membranous structures also accumulated in the astrocytes and were less condensed than typical granular osmiophilic deposits. These results suggest that CtsD deficiency leads to intracellular abnormalities in activated microglia and astrocytes in addition to neuronal degeneration.

10.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37337433

RESUMEN

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Impedancia Eléctrica , Benchmarking , Ablación por Catéter/efectos adversos , Solución Salina
11.
Heliyon ; 9(6): e17394, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37389060

RESUMEN

In-resin CLEM (Correlative Light and Electron Microscopy) of Epon-embedded cells involves correlating fluorescence microscopy with electron microscopy in the same Epon-embedded ultrathin section. This method offers the advantage of high positional accuracy compared to standard CLEM. However, it requires the expression of recombinant proteins. In order to detect the localization of endogenous target(s) and their localized ultrastructures of Epon-embedded samples using in-resin CLEM, we investigated whether immunological and affinity-labeling using fluorescent dyes applied to in-resin CLEM of Epon-embedded cells. The orange fluorescent (λem ∼550 nm) and far-red (λem ∼650 nm) fluorescent dyes examined maintained a sufficient level of fluorescent intensity after staining with osmium tetroxide and subsequent dehydration treatment with ethanol. Immunological in-resin CLEM of mitochondria and the Golgi apparatus was achieved using anti-TOM20, anti-GM130 antibodies, and fluorescent dyes. Two-color in-resin CLEM revealed that wheat germ agglutinin-puncta showed the ultrastructures of multivesicular body-like structures. Finally, taking the advantage of high positional accuracy, volume in-resin CLEM of mitochondria in the semi-thin section (2 µm thick) of Epon-embedded cells was performed by focused ion beam scanning electron microscopy. These results suggested that the application of immunological reaction and affinity-labeling with fluorescent dyes to in-resin CLEM of Epon-embedded cells is suitable for analyzing the localization of endogenous targets and their ultrastructures by scanning and transmission electron microscopy.

12.
Microscopy (Oxf) ; 72(5): 383-387, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37217182

RESUMEN

Correlative fluorescent and electron microscopic images of the same section of epoxy (or other polymer)-embedded samples, hereafter referred to as 'in-resin CLEM', have been developed to improve the positional accuracy and Z-axis resolution limitations of conventional correlative light and electron microscopy (CLEM). High-pressure freezing and quick-freezing substitution result in in-resin CLEM of acrylic-based resin-embedded cells expressing green fluorescent protein, yellow fluorescent protein, mVenus and mCherry, which are sensitive to osmium tetroxide. The identification of osmium-resistant fluorescent proteins leads to the development of in-resin CLEM of Epon-embedded cells. Using subtraction-based fluorescence microscopy with a photoconvertible fluorescent protein, mEosEM-E, its green fluorescence can be observed in thin sections of Epon-embedded cells, and two-color in-resin CLEM using mEosEM-E and mScarlet-H can be performed. Green fluorescent proteins, CoGFP variant 0 and mWasabi, and far-red fluorescent proteins, mCherry2 and mKate2, are available for in-resin CLEM of Epon-embedded cells using the standard procedure for Epon-embedding with additional incubation. Proximity labeling is applied to in-resin CLEM to overcome the limitations of fluorescent proteins in epoxy resin. These approaches will contribute significantly to the future of CLEM analysis.


Asunto(s)
Resinas Epoxi , Humanos , Microscopía Electrónica , Microscopía Fluorescente/métodos , Proteínas Fluorescentes Verdes , Células HeLa
13.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36906814

RESUMEN

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Temperatura , Ablación por Catéter/efectos adversos , Irrigación Terapéutica/efectos adversos , Diseño de Equipo
14.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36852902

RESUMEN

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Ablación por Catéter/efectos adversos , Irrigación Terapéutica/efectos adversos , Diseño de Equipo , Catéteres
15.
Methods Mol Biol ; 2564: 287-297, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36107349

RESUMEN

Postfixation with osmium tetroxide and Epon embedding are essential for the preservation and visualization of subcellular ultrastructures via electron microscopy. These chemical treatments diminish the fluorescent intensity of most fluorescent proteins in cells, creating a problem for the in-resin correlative light-electron microscopy (CLEM) of Epon-embedded mammalian cultured cells. We found that two green and two far-red fluorescent proteins retain their fluorescence after chemical fixation with glutaraldehyde, osmium tetroxide-staining, dehydration, and polymerization of Epon resins. Consequently, we could observe the fluorescence of fluorescent proteins in ultrathin sections of Epon-embedded cells via fluorescence microscopy, investigate ultrastructures of the cells in the same sections via electron microscopy, and correlate the fluorescent image with the electron microscopic image without chemical or physical distortion of the cells. In other words, referred as "in-resin CLEM" of Epon-embedded samples. This technique also improves the Z-axis resolution of fluorescent images. In this chapter, we introduce the detailed protocol for in-resin CLEM of Epon-embedded mammalian cultured cells using these fluorescent proteins.


Asunto(s)
Tetróxido de Osmio , Osmio , Animales , Células Cultivadas , Electrones , Glutaral , Mamíferos , Microscopía Electrónica
16.
J Interv Card Electrophysiol ; 66(4): 885-896, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35451737

RESUMEN

BACKGROUND: The FlexAbility™ SE catheter has a laser-cut 8Fr 4-mm flexible tip irrigated through laser-cut kerfs with a thermocouple 0.3 mm from the distal end. The TactiCath™ SE catheter has an 8Fr 3.5-mm tip and 6-irrigation port with a thermocouple 2.67 mm proximal to the tip. We investigated the impact of these differences on the efficacy and safety of radiofrequency (RF) applications. METHODS: RF applications at a range of powers (20 W, 30 W, and 40 W), contact forces (5 g, 15 g, and 25 g), and durations (10-60 s) using perpendicular/parallel catheter orientation were performed in excised porcine hearts. Lesion characteristics and incidence of steam pops were compared. RESULTS: A total of 540 lesions were examined. The FlexAbility™ SE catheter produced smaller lesion depths (4.0 mm vs. 4.4 mm, p = 0.014 at 20 W; 4.6 mm vs. 5.6 mm, p = 0.015 at 30 W), surface areas (22.7mm2 vs. 29.2mm2 at 20 W, p = 0.005; 23.2mm2 vs. 28.7mm2, p = 0.009 at 30 W), and volumes (126.1mm3 vs. 175.1mm3, p = 0.018 at 20 W; 183.2mm3 vs. 304.3mm3, p = 0.002 at 30 W) with perpendicular catheter placement. However, no differences were observed with parallel catheter placement. Steam-pops were significantly less frequently observed with the FlexAbility™ SE catheter (4% vs. 22%, p < 0.001) irrespective of catheter direction to the tissue. Multivariate analysis showed that use of the TactiCath™ SE catheter, power ≥ 40 W, contact force ≥ 25 g, RF duration > 30 s, parallel angle, and impedance drop ≥ 20Ω were significantly associated with occurrence of steam-pops. CONCLUSIONS: The FlexAbility™ SE catheter reduced the risk of steam-pops but produced smaller lesions with perpendicular catheter placement compared to the TactiCath™ SE catheter.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Irrigación Terapéutica , Diseño de Equipo , Catéteres Cardíacos
17.
Plant Biotechnol (Tokyo) ; 40(1): 93-98, 2023 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38439935

RESUMEN

Nitrogen (N) availability is one of the most important factors regulating plant metabolism and growth as it affects global gene expression profiles. Dynamic changes in chromatin structure, including histone modifications and nucleosome assembly/disassembly, have been extensively shown to regulate gene expression under various environmental stresses in plants. However, the involvement of chromatin related changes in plant nutrient responses has been demonstrated only in a few studies to date. In this study, we investigated the function of histone chaperone NUCLEOSOME ASSEMBLY PROTEIN1 (NAP1) proteins under N deficient conditions in Arabidopsis. In the nap1;1 nap1;2 nap1;3 triple mutant (m123-1), the expression of N-responsive marker genes and growth of lateral roots were decreased under N deficient conditions. In addition, the m123-1 plants showed a delay in N deficiency-induced leaf senescence. Taken together, these results suggest that NAP1s affect plant growth under N deficient conditions in Arabidopsis.

18.
Biochem Biophys Res Commun ; 636(Pt 2): 55-61, 2022 12 25.
Artículo en Inglés | MEDLINE | ID: mdl-36347172

RESUMEN

Ubiquitination is an important post-translational modification that regulates multiple cellular activities in plants including environmental stress responses. In addition to activity of ubiquitin ligases, the activity of deubiquitinating enzymes (DUBs) is critical for modulating the optimal ubiquitination status of target proteins in response to environmental stimuli. However, while several ubiquitin ligases have been isolated to date, little is known about the DUBs involved in plant stress responses. Here, we report that two DUBs, UBP12 and UBP13, function in response to disrupted carbon (C)/nitrogen (N)-nutrient stress conditions in Arabidopsis. Knockdown of UBP12 and UBP13 expression resulted in hypersensitivity to high C/low N-nutrient stress conditions, whereas overexpression of UBP13 reduced the sensitivity. Additionally, UBP13 physically interacted with and deubiquitinated the ubiquitin ligase ATL31, a key regulator of plant resistance to high C/low N-nutrient stress conditions. Genetic analysis showed that the loss of ATL31 and its homolog ATL6 suppressed the high C/low N-hyposensitivity of UBP13-overexpressing plants, suggesting that ATL31 is epistatic to UBP12 and UBP13. Taken together, our results suggest that the DUBs UBP12 and UBP13 function together with the ubiquitin ligase ATL31 to mediate C/N-nutrient stress responses in plants.


Asunto(s)
Proteínas de Arabidopsis , Arabidopsis , Arabidopsis/metabolismo , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Nitrógeno/metabolismo , Ubiquitina/metabolismo , Carbono/metabolismo , Regulación de la Expresión Génica de las Plantas , Plantas Modificadas Genéticamente/genética , Ubiquitinación , Ubiquitina-Proteína Ligasas/genética , Ubiquitina-Proteína Ligasas/metabolismo , Nutrientes , Enzimas Desubicuitinizantes/metabolismo , Endopeptidasas/metabolismo
19.
FEBS Lett ; 596(22): 2873-2888, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36056653

RESUMEN

The Golgi pH regulator (GPHR) is essential for maintaining the function and morphology of the Golgi apparatus through the regulation of luminal acidic pH. Abnormal morphology of the Golgi apparatus is associated with neurodegenerative diseases. Here, we found that knockout of GPHR in the mouse brain led to morphological changes in the Golgi apparatus and neurodegeneration, which included brain atrophy, neuronal cell death, and gliosis. Furthermore, in the GPHR knockout mouse brain, transcriptional activity of sterol regulatory element-binding protein 2 (SREBP2) decreased, resulting in a reduction in cholesterol levels. GPHR-deficient cells exhibited suppressed neurite outgrowth, which was recovered by exogenous expression of the active form of SREBP2. Our results show that GPHR-mediated luminal acidification of the Golgi apparatus maintains proper cholesterol levels and, thereby, neuronal morphology.


Asunto(s)
Aparato de Golgi , Proteína 2 de Unión a Elementos Reguladores de Esteroles , Animales , Ratones , Aparato de Golgi/metabolismo , Proteína 2 de Unión a Elementos Reguladores de Esteroles/genética , Proteína 2 de Unión a Elementos Reguladores de Esteroles/metabolismo , Ratones Noqueados , Colesterol/metabolismo , Concentración de Iones de Hidrógeno , Encéfalo/metabolismo
20.
Plant Biotechnol (Tokyo) ; 39(2): 173-177, 2022 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-35937525

RESUMEN

3-Phenyllactic acid (PLA) is a common secondary product of Lactobacillus sp. and promotes adventitious-root formation in Azuki beans (Vigna angularis). Root promotion activity of PLA is synergistically enhanced by tryptophan (Trp). In this study, stereoisomers of PLA and Trp amide conjugates and their alkyl esters were synthesized to investigate the structure-activity relationships on root-promotion activity. The rooting activity of D-PLA-L-Trp conjugate shows more than 40 times higher than that of the mixture of D-PLA and L-Trp. Modification of PLA-Trp with ethyl ester showed the highest activity at 3,400 times of a mixture of D-PLA and L-Trp. However, L-or D-PLA-D-Trp conjugate and the isopropyl ester of PLA-Trp conjugates, both lost the root promotion activity and implicated that a requirement for steric structure for PLA related root promotion mechanism. Unlike auxin substances, which are commonly used as rooting agents that displayed high activity in low concentrations, PLA-Trp ethyl ester exhibited far less phytotoxicity at high concentration of 1 mM, despite its high rooting activity. Innovation of PLA-Trp ethyl ester may be expected for agricultural aspects with low environmental impact.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...